About lab
One published Lab
Build with this Lab. Run it anywhere.
Use the same immutable release locally or through managed cloud execution, with its exact version and provenance preserved.
Preparing exact examples…
Two-model lab for Guyton1972 Capillary Dynamics: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.
Manifest
{
"io": {
"inputs": [
{
"name": "integration_step",
"maps_to": "guyton1972_capillary_dynamics_core.integration_step"
},
{
"name": "parameter_overrides",
"maps_to": "guyton1972_capillary_dynamics_core.parameter_overrides"
},
{
"name": "initial_conditions",
"maps_to": "guyton1972_capillary_dynamics_core.initial_conditions"
}
],
"outputs": [
{
"name": "scenario_metadata",
"maps_to": "guyton1972_capillary_dynamics_scenario.scenario_metadata"
},
{
"name": "state",
"maps_to": "guyton1972_capillary_dynamics_core.state"
},
{
"name": "run_summary",
"maps_to": "guyton1972_capillary_dynamics_viz.run_summary"
}
]
},
"title": "Guyton1972 Capillary Dynamics Lab",
"models": [
{
"path": "models/scenario",
"alias": "guyton1972_capillary_dynamics_scenario",
"parameters": {
"schedule": {
"capillary_pressure": {
"unit": "dimensionless",
"label": "capillary pressure",
"active": true,
"baseline": 16.9144,
"recovery": 16.9144,
"challenge": 20.29728,
"description": "Scenario-controlled capillary pressure value."
},
"filtration_coefficient": {
"unit": "dimensionless",
"label": "filtration coefficient",
"active": false,
"baseline": -4.078e-7,
"recovery": -4.078e-7,
"challenge": -4.078e-7,
"description": "Scenario-controlled filtration coefficient value."
}
},
"scenario_name": "Pressure-load challenge",
"baseline_until": 150,
"challenge_until": 450,
"scenario_description": "Baseline is followed by a capillary pressure challenge and recovery period."
}
},
{
"path": "models/core",
"alias": "guyton1972_capillary_dynamics_core",
"parameters": {
"model_path": "data/MODEL0912160000.xml",
"integration_step": 1
}
},
{
"path": "models/viz",
"alias": "guyton1972_capillary_dynamics_viz",
"parameters": {
"lab_title": "Guyton1972 Capillary Dynamics",
"lab_question": "Does fluid move into or out of the capillaries?",
"integration_step": 1
}
}
],
"wiring": [
{
"to": [
"guyton1972_capillary_dynamics_core.capillary_pressure"
],
"from": "guyton1972_capillary_dynamics_scenario.capillary_pressure"
},
{
"to": [
"guyton1972_capillary_dynamics_core.filtration_coefficient"
],
"from": "guyton1972_capillary_dynamics_scenario.filtration_coefficient"
},
{
"to": [
"guyton1972_capillary_dynamics_viz.scenario_metadata"
],
"from": "guyton1972_capillary_dynamics_scenario.scenario_metadata"
},
{
"to": [
"guyton1972_capillary_dynamics_viz.state"
],
"from": "guyton1972_capillary_dynamics_core.state"
},
{
"to": [
"guyton1972_capillary_dynamics_viz.species_labels"
],
"from": "guyton1972_capillary_dynamics_core.species_labels"
}
],
"package": "guyton1972-capillary-dynamics",
"runtime": {
"duration": 600,
"initial_inputs": {
"guyton1972_capillary_dynamics_core": {
"integration_step": 1,
"initial_conditions": {
"payload": {}
},
"parameter_overrides": {
"payload": {}
}
}
},
"communication_step": 1
},
"version": "1.0.0",
"description": "Two-model lab for Guyton1972 Capillary Dynamics: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.",
"schema_version": "2.0"
}Runtime
Duration600
Comms Step1
Runs
Total0
Completed0
Failed0
Metadata
Packageguyton1972-capillary-dynamics
Created2026-05-14
Updated2026-06-13
cardiovascularscenariostimulussbmlbiomodels_ebifaithfulvisualizationother