About lab
One published Lab
Build with this Lab. Run it anywhere.
Use the same immutable release locally or through managed cloud execution, with its exact version and provenance preserved.
Preparing exact examples…
Two-model lab for Guyton1972 Volume Receptors: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.
Manifest
{
"io": {
"inputs": [
{
"name": "integration_step",
"maps_to": "guyton1972_volume_receptors_core.integration_step"
},
{
"name": "parameter_overrides",
"maps_to": "guyton1972_volume_receptors_core.parameter_overrides"
},
{
"name": "initial_conditions",
"maps_to": "guyton1972_volume_receptors_core.initial_conditions"
}
],
"outputs": [
{
"name": "scenario_metadata",
"maps_to": "guyton1972_volume_receptors_scenario.scenario_metadata"
},
{
"name": "state",
"maps_to": "guyton1972_volume_receptors_core.state"
},
{
"name": "run_summary",
"maps_to": "guyton1972_volume_receptors_viz.run_summary"
}
]
},
"title": "Guyton1972 Volume Receptors Lab",
"models": [
{
"path": "models/scenario",
"alias": "guyton1972_volume_receptors_scenario",
"parameters": {
"schedule": {
"right_atrial_pressure": {
"unit": "dimensionless",
"label": "right atrial pressure",
"active": true,
"baseline": 0.00852183,
"recovery": 0.00852183,
"challenge": 0.010226195999999998,
"description": "Scenario-controlled right atrial pressure value."
}
},
"scenario_name": "Pressure-load challenge",
"baseline_until": 150,
"challenge_until": 450,
"scenario_description": "Baseline is followed by a right atrial pressure challenge and recovery period."
}
},
{
"path": "./models/core",
"alias": "guyton1972_volume_receptors_core",
"parameters": {
"model_path": "data/MODEL0909931851.xml",
"integration_step": 1
}
},
{
"path": "./models/viz",
"alias": "guyton1972_volume_receptors_viz",
"parameters": {
"lab_title": "Guyton1972 Volume Receptors",
"lab_question": "Do volume receptors detect volume expansion?",
"integration_step": 1
}
}
],
"wiring": [
{
"to": [
"guyton1972_volume_receptors_core.right_atrial_pressure"
],
"from": "guyton1972_volume_receptors_scenario.right_atrial_pressure"
},
{
"to": [
"guyton1972_volume_receptors_viz.scenario_metadata"
],
"from": "guyton1972_volume_receptors_scenario.scenario_metadata"
},
{
"to": [
"guyton1972_volume_receptors_viz.state"
],
"from": "guyton1972_volume_receptors_core.state"
},
{
"to": [
"guyton1972_volume_receptors_viz.species_labels"
],
"from": "guyton1972_volume_receptors_core.species_labels"
}
],
"package": "guyton1972-volume-receptors",
"runtime": {
"duration": 600,
"initial_inputs": {
"guyton1972_volume_receptors_core": {
"integration_step": 1,
"initial_conditions": {
"payload": {}
},
"parameter_overrides": {
"payload": {}
}
}
},
"communication_step": 1
},
"version": "1.0.0",
"description": "Two-model lab for Guyton1972 Volume Receptors: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.",
"schema_version": "2.0"
}Runtime
Duration600
Comms Step1
Runs
Total0
Completed0
Failed0
Metadata
Packageguyton1972-volume-receptors
Created2026-05-14
Updated2026-06-13
cardiovascularscenariostimulussbmlbiomodels_ebifaithfulvisualizationother